TDK EPCOS GDT Gas Discharge Tube Surge Arrester B88069X9891* A70-H15X
Electrical specifications
DC spark-over voltage 1) 2) |
1500 |
V |
Tolerance |
±13 |
% |
Min. |
1300 |
V |
Max. |
1700 |
V |
Impulse spark-over voltage |
|
|
at 100 V/µs - for 99% of measured values |
< 2300 |
V |
- typical values of distribution |
< 2200 |
V |
at 1 kV/µs - for 99% of measured values |
< 2400 |
V |
- typical values of distribution |
< 2300 |
V |
Service life 10 operations 50 Hz, 1 s 1 operation 50 Hz, 0.18 s (9 cycles) 10 operations 8/20 µs 1 operation 8/20 µs |
10 |
A |
65 |
A |
|
10 |
kA |
|
15 |
kA |
|
Insulation resistance at 100 VDC |
> 10 |
GW |
Capacitance at 1 MHz |
< 1 |
pF |
Arc voltage at 1 A |
~ 20 |
V A V |
Glow to arc transition current |
< 1 |
|
Glow voltage |
~ 180 |
|
Weight |
~ 1.5 |
g |
Operation and storage temperature |
-40 ... +125 |
°C |
Climatic category (IEC 60068-1) |
40/125/21 |
|
Marking, green positive |
1500 YY O 1500 - Nominal voltage YY - Year of production O - Non radioactive |
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
Terms in accordance with ITU-T Rec. K.12; IEC 61663-2 and IEC 61643-311.
Dimension
Dimensional drawing in mm