TDK EPCOS GDT Gas Discharge Tube Surge Arrester B88069X4293* 2-electrode arrester EM90XHC
Electrical specifications
DC spark-over voltage 1) 2) |
90 |
V |
|
Tolerance |
±20 |
% |
|
Min. |
72 |
V |
|
Max. |
108 |
V |
|
Impulse spark-over voltage |
< 400 |
|
|
at 100 V/µs - for 99% of measured values |
|
V |
|
- typical values of distribution |
|
V |
|
at 1 kV/µs - for 99% of measured values |
|
V |
|
- typical values of distribution |
|
V |
|
Service life 1 operation 50Hz, 0.18s(9 cycles) |
10 |
A |
|
|
20 |
A |
|
|
10 |
kA |
|
|
1 |
kA |
|
|
100 |
A |
|
Insulation resistance at 50 VDC |
> 1 |
GW |
|
Capacitance at 1 MHz |
< 1 |
pF |
|
Arc voltage at 1 A |
~ 10 |
V A V |
|
Glow to arc transition current |
< 0.1 |
|
|
Glow voltage |
~ 50 |
|
|
Weight |
~ 1 |
g |
|
Operation and storage temperature |
-40 ... +125 |
°C |
|
Climatic category (IEC 60068-1) |
40/125/21 |
||
Marking, blue positive |
EM 90 O |
EM 90 YY OO - Nominal voltage |
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
Terms in accordance with ITU-T Rec. K.12 and IEC 61643-311.