TDK EPCOS GDT Gas Discharge Tube Surge Arrester B88069X2250S102 A81-A230X
Electrical specifications
DC spark-over voltage 1) 2) |
230 ± 20 |
V % |
|
Impulse spark-over voltage |
|
|
|
at 100 V/µs - for 99% of measured values |
< 500 |
V |
|
- typical values of distribution |
< 450 |
V |
|
at 1 kV/µs - for 99% of measured values |
< 650 |
V |
|
- typical values of distribution |
< 550 |
V |
|
Service life 8) |
|||
10 operations 50 Hz; 1 s |
20 |
A |
|
1 operation 50 Hz; 0.18 s (9 cycles) |
100 |
A |
|
10 operations 8/20 µs |
20 |
kA |
|
1 operation 8/20 µs |
25 |
kA |
|
1 operation 10/350 µs |
2.5 |
kA |
|
300 operations 10/1000 µs |
200 |
A |
|
Insulation resistance at 100 VDC |
> 10 |
GΩ |
|
Capacitance at 1 MHz |
< 1.5 |
pF |
|
Arc voltage at 1 A |
~ 15 |
V A V |
|
Glow to arc transition current |
~ 0.5 |
||
Glow voltage |
~ 60 |
||
Weight |
~ 2.5 |
g |
|
Operation and storage temperature |
-40 ... +90 |
°C |
|
Climatic category (IEC 60068-1) |
40/ 90/ 21 |
||
Marking, blue negative |
230 YY O |
230 YY O - Nominal voltage - Year of production - Non radioactive |
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
Terms in accordance with ITU-T Rec. K.12; IEC 61663-2 and IEC 61643-311.