Leave Your Message
TDK EPCOS GDT Gas Discharge Tube Surge Arrester B88069X1493* 2-electrode arrester EM3600XS

Products are gradually online,we have all the models, welcome to consult us!

2 pole

TDK EPCOS GDT Gas Discharge Tube Surge Arrester B88069X1493* 2-electrode arrester EM3600XS

Ordering code: B88069X1493T502

Series/Type: EM3600XS

Nominal DC sparkover voltage: 3600 V

Service life: Nominal impulse discharge current: 2 KA

    Electrical specifications

    Electrical specifications

    DC spark-over voltage 1) 2)

    3600

    V

    Tolerance

    ±20

    %

    Min.

    2880

    V

    Max.

    4320

    V

    Impulse spark-over voltage

     

     

    at 100 V/µs    - for 99% of measured values

    < 4350

    V

    - typical values of distribution

    < 4150

    V

    at 1 kV/µs     - for 99% of measured values

    < 4500

    V

    - typical values of distribution

    < 4300

    V

    at 5 kV/µs     - for 99% of measured values

    < 5000

    V

    - typical values of distribution

    < 4500

    V

    Service life

     

     

    10 operations                              50Hz, 1 s

    1

    A

    1000 operations                                    8/20 µs

    100

    A

    10 operation [10× (+) & 10× (-)]                   8/20 µs

    3

    kA

    1 operation                                 8/20 µs

    5

    kA

    Insulation resistance at 100 VDC

    > 1

    GW

    Capacitance at 1 MHz

    < 1

    pF

    Arc voltage at 1 A

    ~ 35

    V

    Glow to arc transition current

    < 0.3

    A

    Glow voltage

    ~ 170

    V

    Weight

    ~ 1

    g

    Operation and storage temperature

    -40 ... +125

    °C

    Recommended storage

    ~ 1

    g

    -temperature

    -5 ... +35

    °C

    -humidity

    45...80

    %

    -period

    ≤2

    years

    Climatic category (IEC 60068-1)

    40/125/21

    Marking, red positive

     

    EM 3600 YY OO

    EM

    -Series

    3600

    - Nominal voltage

    YY

    - Year of production

    O

    - Non radioactive

    Certification

    UL 1449 (E319264)

    1)     At delivery AQL 0.65 level II, DIN ISO 2859

    2)     In ionized mode

    3)     Test conditions in acc. with MIL-STD-202G at 25 ±5 °C, relative humidity of ≤ 55 % and atmospheric pressure

    860 ... 1100mbar.

    Terms and current waveforms in accordance with: ITU-T Rec. K. 12; IEC 61643-21; 61643-311.



    Dimension

    Dimensional drawing in mm

    pp1xsc

    The Others

    • FEATURES

      Very small size
      Extremely fast response time
      Stable performance over service life
      Extremely low capacitance
      High insulation resistance
      RoHS-compatible

    • APPLICATIONS

      Modem
      XDSL-splitter
      Station protection
      Consumer electronics
      Tuner

     
    Contact us for more technical support!
    For information about packaging, transportation, delivery, after-sales, settlement, certification, etc., you can see About UsFAQS

    Leave Your Message