TDK EPCOS GDT Gas Discharge Tube B88069X5010* M51-C90X
Electrical specifications
DC spark-over voltage 1) 2) |
90 |
V |
||
Tolerance |
±20 |
% |
||
Min. |
72 |
V |
||
Max. |
108 |
V |
||
Impulse spark-over voltage |
|
|
||
at 100 V/µs |
- for 99% of measured values |
< 400 |
V |
|
- typical values of distribution |
< 300 |
V |
||
at 1 kV/µs |
- for 99% of measured values |
< 600 |
V |
|
- typical values of distribution |
< 550 |
V |
||
Service life |
|
|
|
|
10 operations |
50 Hz, 1 s |
5 |
A |
|
1 operation |
50 Hz, 0.18 s (9 cycles) |
10 |
A |
|
10 operations |
8/20 µs |
5 |
kA |
|
1 operation |
8/20 µs |
10 |
kA |
|
1 operation |
10/350 µs |
0.5 |
kA |
|
300 operations |
10/1000 µs |
100 |
A |
|
Insulation resistance at 50 VDC |
> 1 |
GΩ |
||
Capacitance at 1 MHz |
< 1 |
pF |
||
Arc voltage at 1 A |
~ 15 |
V |
||
Glow to arc transition current |
< 0.8 |
A |
||
Glow voltage |
~ 60 |
V |
||
Weight |
~ 1 |
g |
||
Operation and storage temperature |
-40 ... +90 |
°C |
||
Climatic category (IEC 60068-1) |
40/090/21 |
|||
Marking, blue negative |
90 YY O |
|
||
90 |
- Nominal voltage |
|||
YY |
- Year of production |
|||
O |
- Non radioactive |
|||
Certifications |
UL 497B (E163070) |
The Others
Our price of GDT is particularly good. Because we have been serving many customers in the lightning protection industry for decades.
So we also have high quality lightning protection products.
-
Applications: