TDK EPCOS GDT Gas Discharge Tube B88069X4131* EF270X
Electrical specifications
DC spark-over voltage 1) 2) |
270 |
V |
Tolerance Min. Max. |
-15 … +25 230 338 |
% V V |
Impulse spark-over voltage |
|
|
at 100 V/µs - for 99% of measured values |
< 500 |
V |
- typical values of distribution |
< 450 |
V |
at 1 kV/µs - for 99% of measured values |
< 550 |
V |
- typical values of distribution |
< 500 |
V |
Service life 10 operations 50 Hz, 1 s 1 operation 50 Hz, 0.18 s (9 cycles) 10 operations 8/20 µs 1 operation 8/20 µs |
5 |
A |
65 |
A |
|
5 |
kA |
|
10 |
kA |
|
Max. follow current during one voltage half cycle at 50 Hz |
200 |
A |
Insulation resistance at 100 VDC |
> 10 |
GΩ |
Capacitance at 1 MHz |
< 1.5 |
pF |
Arc voltage at 1 A |
~ 16 |
V A V |
Glow to arc transition current |
< 0.3 |
|
Glow voltage |
~ 140 |
|
Weight |
~ 1.5 |
g |
Operation and storage temperature |
-40 ... +125 |
°C |
Climatic category (IEC 60068-1) |
40/125/21 |
|
Marking, red positive |
EF 270 YY O EF - Series 270 - Nominal voltage YY - Year of production O - Non radioactive |
|
Certification |
UL 1449 (E319264) |
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
Terms in accordance with ITU-T Rec. K.12 and IEC 61643-311.
The Others
Our price of GDT is particularly good. Because we have been serving many customers in the lightning protection industry for decades.
So we also have high quality lightning protection products.
-
Applications:
Application with high follow currentPower supply