TDK EPCOS GDT Gas Discharge Tube B88069X2840S102 A81-A150X
Electrical specifications
DC spark-over voltage 1) 2) |
150 |
V |
|
Tolerance |
±20 |
% |
|
Min. |
120 |
V |
|
Max. |
180 |
V |
|
Impulse spark-over voltage |
|
|
|
at 100 V/µs - for 99% of measured values |
< 500 |
V |
|
- typical values of distribution |
< 450 |
V |
|
at 1 kV/µs - for 99% of measured values |
< 600 |
V |
|
- typical values of distribution |
< 550 |
V |
|
Service life |
|
|
|
10 operations 50 Hz, 1 s |
20 |
A |
|
1 operation 50 Hz, 0.18 s (9 cycles) |
100 |
A |
|
10 operations [5× (+) & 5× (–)] 8/20 µs |
20 |
kA |
|
1 operation 8/20 µs |
25 |
kA |
|
10 operations [5× (+) & 5× (–)] 10/350 µs |
3 |
kA |
|
300 operations 10/1000 µs |
200 |
A |
|
Insulation resistance at 100 VDC |
> 10 |
GΩ |
|
Capacitance at 1 MHz |
< 1.5 |
pF |
|
Arc voltage at 1 A |
~ 15 |
V |
|
Glow to arc transition current |
< 0.6 |
A |
|
Glow voltage |
~ 60 |
V |
|
Weight |
~ 1.5 |
g |
|
Operation and storage temperature |
-40 ... +125 |
°C |
|
Climatic category (IEC 60068-1) |
40/125/21 |
||
Marking, blue negative |
150 YY O |
||
150 |
- Nominal voltage |
||
YY |
- Year of production |
||
O |
- Non radioactive |
||
Certification |
UL 497B (E163070) |
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
Terms in accordance with ITU-T Rec. K.12 and IEC 61643-311.
The Others
Our price of GDT is particularly good. Because we have been serving many customers in the lightning protection industry for decades.
So we also have high quality lightning protection products.
-
Applications:
Consumer electronicsPower supply