TDK EPCOS GDT Gas Discharge Tube B88069X1203* EM3600X6ST7
Electrical specifications
DC spark-over voltage 1) 2) |
3600 |
V |
Tolerance |
±20 |
% |
Min. |
2880 |
V |
Max. |
4320 |
V |
Impulse spark-over voltage |
|
|
at 100 V/µs - for 99% of measured values |
< 4350 |
V |
- typical values of distribution |
< 4150 |
V |
at 1 kV/µs- for 99% of measured values |
< 4500 |
V |
- typical values of distribution |
< 4300 |
V |
at 5 kV/µs- for 99% of measured values |
< 5000 |
V |
- typical values of distribution |
< 4500 |
V |
Service life
10 operations 50 Hz; 1 s 300 operations 8/20 µs 10 operations 8/20 µs 1 operation 8/20 µs |
1 |
A |
100 |
A |
|
3 |
kA |
|
5 |
kA |
|
Insulation resistance at 100 VDC |
> 1 |
GW |
Capacitance at 1 MHz |
< 1 |
pF |
Arc voltage at 1 A |
~ 35 |
V A V |
Glow to arc transition current |
< 0.3 |
|
Glow voltage at 0.1 A |
~ 170 |
|
AC withstand voltage 3) |
|
|
1 min |
1500 |
V |
1 s |
1800 |
V |
Weight |
~ 1 |
g |
Operation temperature |
‒40 ... +125 |
°C |
Recommended storage |
|
|
- temperature |
+5 ... +35 |
°C |
- humidity |
45 ... 80 |
% |
- period |
≤ 2 |
years |
Climatic category (IEC 60068-1) |
40/125/21 |
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
3) Test conditions in acc. with MIL-STD-202G at 25 ±5 °C, relative humidity of 55 % and atmospheric pressure 860 ... 1100mbar.
Terms and current waveforms in accordance with: ITU-T Rec. K. 12; IEC 61643-21; 61643-311.
The Others
Our price of GDT is particularly good. Because we have been serving many customers in the lightning protection industry for decades.
So we also have high quality lightning protection products.
-
Applications:
Consumer electronicsPower supply